Terms beginning with I
13 of 238 glossary terms.
- Ion-pair chromatography
- Adding an amphiphilic counter-ion to the mobile phase so a charged analyte forms a neutral pair with enough hydrophobic character to be retained on C18.
- Isocratic
- Constant mobile-phase composition throughout the run. Simpler, and unsuitable for samples spanning a wide hydrophobicity range.
- Identification threshold
- The level above which an impurity must be structurally identified rather than merely quantified. ICH Q3A sets it by daily dose.
- Ion suppression
- Reduction in analyte ionisation caused by a co-eluting species or a mobile-phase additive. Trifluoroacetic acid is a strong suppressor.
- Isotope pattern
- The set of peaks arising from natural isotopic variants of a molecule. Its spacing gives the charge state directly: 1/z daltons.
- Ion chromatography
- Separation of ions on an ion-exchange column with suppressed conductivity detection. The reference technique for counter-ion quantification.
- ICP-MS
- Inductively coupled plasma mass spectrometry. Elemental analysis. Required for metal-complexed peptides and for elemental impurity profiles.
- Isoaspartate
- The rearranged product of deamidation via a succinimide intermediate. Mass-identical to aspartate-containing peptide.
- Impurity fingerprint
- The vector of named impurities and their levels in a lot. Characteristic of one manufacturing run; used by the index to identify shared bulks.
- Inhibition/enhancement control
- A spike of standard endotoxin added to the sample to show the matrix does not interfere. Must recover at 50–200 % or the result is invalid.
- Interquartile range (IQR)
- The difference between the 75th and 25th percentiles. The index's preferred spread statistic because purity distributions are left-skewed.
- Intermediate precision
- Precision across days, analysts and instruments within one laboratory. Wider than repeatability and more realistic.
- Index reference method RG-2
- The index's nominated reverse-phase method: C18 2.6 µm, 0.1 % TFA, 5→65 % acetonitrile over 30 min at 40 °C, 214 nm. All retention windows are stated against it.
see also HILIC
see also Gradient
see also Reporting threshold · Qualification threshold
see also Trifluoroacetic acid (TFA)
see also Monoisotopic mass · Average mass
see also Counter-ion
see also Metal complex · Elemental impurity
see also Deamidation · Aspartimide
see also Rule AX-R09 · Shared bulk
see also LAL
see also Repeatability · Reproducibility
see also Gradient normalisation