AssayIndex

AX-2026-041339

CJC-1295 with DAC · 2 mg declared · Wuhan Wansheng Biotechnology Co., Ltd. · lot WWB-2508-V3100

MARGINALVERIFIED
Report ID
AX-2026-041339
Compound
CJC-1295 with DAC
Compound class
Growth-hormone axis peptides
Supplier
WWB — Wuhan Wansheng Biotechnology Co., Ltd.
Batch / lot
WWB-2508-V3100
Declared label claim
2mg
Laboratory
PeptideMeter
Assay date
26 Feb 2026
Submitted
09 Mar 2026
Quarter
2026-Q1
Submitter
ch.dahlberg
Sample provenance
Supplier-supplied
Section 1

Results

Measured against the index acceptance specification for the growth-hormone axis peptides class. A specification is a decision the index made; a result is a measurement. See where each threshold came from.

ParameterMethodResultUnitIndex spec
PurityRP-HPLC, 28 min gradient, 214 nm99.52% area≥ 97.5PASS
Total impuritiesRP-HPLC, sum of reported peaks0.48% area≤ 2.5PASS
Largest single impurityRP-HPLC — hydrolysed maleimide (+18 Da)0.35% area≤ 1.00PASS
Identity — theoretical monoisotopic masscalculated from molecular formula3644.9748DaNOT TESTED
Identity — observed monoisotopic massLC-MS, high resolution (ESI-TOF/QTOF)3644.9814DaNOT TESTED
Mass accuracyobserved vs theoretical+1.8ppm± 15PASS
Peptide contentnot ordered on this submissionnot determinedrequired to check label claimNOT TESTED
Water contentKarl Fischer, coulometric, duplicate6.24%≤ 9.0PASS
Counter-ion (acetate)anion-exchange ion chromatography5.07%≤ 12.0PASS
Residual solvent + inorganic residueestimated — see /methods/residual-solvents-q3c/0.32%NOT TESTED
Endotoxinkinetic chromogenic LAL1.92EU/mg≤ 5.0PASS
Sterilitynot ordered on this submissionnot determinedno growthNOT TESTED
Appearancevisual, diffuse light, black and white backgroundOff-white lyophilised cake, intactwhite to off-white intact cakePASS
Reconstitution clarityreconstituted per submitter procedureClear, colourless, no visible particulatesclear, no visible particulatesPASS
pH (reconstituted, 1 mg/mL)potentiometric, two-point calibration5.002.5 – 8.0PASS
Retention time (observed)RP-HPLC, 28 min gradient13.59min13.72 ± 0.35 (normalised)PASS
Peak asymmetry (10 % height)Ph. Eur. 2.2.460.940.80 – 1.50PASS
Plate count, main peakN = 5.54 (t/w½)²72,595≥ 20,000PASS
Resolution to nearest impurityvs deamidated (+1 Da)1.17no index criterionREPORTED
Section 2

Chromatogram and peak integration

The figure is drawn from the table. It is not an independent illustration — if a number in the table changed, the trace would change with it.

02355470970649418 CJC-1295 with DAC13.59 min · 99.52 % 13.0115.85 same trace · ×100 vertical expansion, baseline-corrected · main peak off-scale reporting threshold 0.05 % area 051015202530 Retention time (min) Response (mAU)
Figure 1. RP-HPLC trace, 28 min gradient, 214 nm. Drawn from the peak-integration table below: peak positions are the reported retention times, peak areas are the reported area percentages, peak widths follow the reported plate count of 72,595, and skew follows the reported asymmetry factor of 0.94. Baseline noise is seeded from the report ID and is illustrative. The lower panel is the same trace at a stated vertical expansion with the slow gradient drift subtracted, because at full scale a 0.35 % impurity against a 99.52 % main peak is a line two pixels tall; the main peak runs off-scale there by design.
#PeakRTArea (µV·s)% areaΔ mass (Da)
1CJC-1295 with DAC — main peak13.594,836,98199.52
2hydrolysed maleimide (+18 Da)13.0117,0110.35+18.011
3maleimide dimer15.853,4020.07+3644.975
4deamidated (+1 Da)13.351,4580.03+0.984
5mod-GRF (1-29) (−279 Da)11.951,4580.03-279.235
Closure check — purity + Σ impurities 100.00CLOSES

Reporting threshold 0.05 % area. Peaks below it are not reported and are therefore excluded from the total, which overstates purity by their sum — see peak integration.

Section 3

Mass spectrum and identity

Theoretical monoisotopic mass 3644.9748 Da, computed from C165H269N47O46. All ppm figures on this site are against monoisotopic values — see why that matters.

025507510057580010251250147517001925 [M+3H]3+1216.00[M+2H]2+1823.50[M+4H]4+912.25 m/z Relative abundance (%)
Figure 2. ESI charge-state envelope, high-resolution instrument. Sticks are placed at m/z = (M + z × 1.007276)/z for the observed neutral mass of 3644.9814 Da. Sodium (+21.982/z) and potassium (+37.956/z) adducts are shown where the parent charge state exceeds 25 % relative abundance; they are adducts of the same molecule and are not impurities.
ChargeTheoretical m/zObserved m/zΔ m/zRel. abundance (%)
5+730.0022730.00360.00148.2
4+912.2510912.25260.001654.9
3+1215.99891216.00110.0022100.0
2+1823.49471823.49800.003355.7
Section 4

Gravimetric mass balance

Water, counter-ion, residual and total peptide content are exhaustive and mutually exclusive categories. They must account for 100 % of the cake mass. The index closes this to within 0.02 pp and the build asserts it.

Supplier certificate, as declared

The supplier's own figures for this lot, beside the independent measurement. Divergence is assessed against the batch median, not against this single report — see rule AX-R05.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.52divergence +0.10 pp vs batch median
Total impurities (% area)not stated0.48
Largest single impurity (% area)not stated0.35
Water (%)not stated6.24
Counter-ion (%)3.85.07
Peptide content (%w/w)96.1not determined
Endotoxin (EU/mg)not stated1.92
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Provenance and caveats

Where a sample came from changes the weight of the evidence. The index treats it as a first-class field.

Sample provenance
Supplier-supplied
Evidentiary weight
Weaker evidence. Read with the caveat below.
Chain of custody
Supplier despatch → laboratory direct (courier, cold pack, 8 d) → assay. Submitter did not handle the vial.
Assay date
26 Feb 2026
Submitted to the index
09 Mar 2026
Laboratory
PeptideMeter, Tallinn, Estonia
Method basis
28 min gradient · high-resolution MS
Verification status
VERIFIED
Section 6

Annotations

No annotations on this record. Annotations are short signed technical comments from index contributors; see how to contribute.

Section 7

Related records

Same batch — lot WWB-2508-V3100 n=11

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041340WWB-2508-V3100Janoshik2026-Q199.936.19Supplier-supplied1MARGINAL
AX-2026-041341WWB-2508-V3100Medutest2026-Q199.936.30Supplier-supplied0PASS
AX-2026-041342WWB-2508-V3100Janoshik2026-Q199.545.42Supplier-supplied0PASS
AX-2026-041343WWB-2508-V3100Kestrel2026-Q199.935.79106.0Supplier-supplied1FAIL
AX-2026-041344WWB-2508-V3100Janoshik2026-Q199.805.4396.6Supplier-supplied1MARGINAL
AX-2026-041345WWB-2508-V3100Janoshik2026-Q199.506.14Supplier-supplied1MARGINAL
AX-2026-041346WWB-2508-V3100PeptideMeter2026-Q199.935.1395.3Supplier-supplied0PASS
AX-2026-041347WWB-2508-V3100Medutest2026-Q199.305.74Supplier-supplied1MARGINAL
AX-2026-041348WWB-2508-V3100Janoshik2026-Q199.396.15Supplier-supplied1MARGINAL
AX-2026-041349WWB-2508-V3100Nordanalyt2026-Q199.936.67Supplier-supplied0PASS
Other recent CJC-1295 with DAC records in the index.
ReportSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041727QSCQSC-2602-E9474Janoshik2026-Q398.886.62105.3Supplier-supplied1MARGINAL
AX-2026-041728QSCQSC-2602-E9474VendorInvestigate2026-Q398.427.04Buyer-sourced1MARGINAL
AX-2026-041734QSCQSC-2602-E9474Medutest2026-Q399.437.17105.5Supplier-supplied2FAIL
AX-2026-043539BCHBCH-2607-H7307Janoshik2026-Q398.125.78100.6Supplier-supplied1MARGINAL
AX-2026-041730QSCQSC-2602-E9474PeptideMeter2026-Q398.796.9395.4Supplier-supplied1MARGINAL
AX-2026-041731QSCQSC-2602-E9474VendorInvestigate2026-Q399.077.1899.6Buyer-sourced1MARGINAL
AX-2026-041725QSCQSC-2602-E9474Medutest2026-Q399.067.04107.3Supplier-supplied2FAIL
AX-2026-043537BCHBCH-2607-H7307Janoshik2026-Q398.455.49103.1Supplier-supplied1MARGINAL
Other recent WWB records in the index.
ReportCompoundLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041275LiraglutideWWB-2607-X2189Nordanalyt2026-Q399.615.0397.3Supplier-supplied0PASS
AX-2026-041387BPC-157WWB-2606-H3906Janoshik2026-Q398.954.64Laboratory-retained1MARGINAL
AX-2026-041334SemaglutideWWB-2606-N3192Janoshik2026-Q398.835.04Supplier-supplied1MARGINAL
AX-2026-041337SemaglutideWWB-2606-N3192Nordanalyt2026-Q398.964.81Supplier-supplied1MARGINAL
AX-2026-041385BPC-157WWB-2606-H3906Medutest2026-Q399.314.31Supplier-supplied1MARGINAL
AX-2026-041390BPC-157WWB-2606-H3906Medutest2026-Q399.474.8499.3Supplier-supplied1MARGINAL
AX-2026-041386BPC-157WWB-2606-H3906VendorInvestigate2026-Q399.324.8899.2Buyer-sourced1MARGINAL
AX-2026-041335SemaglutideWWB-2606-N3192Janoshik2026-Q399.554.55100.5Supplier-supplied1MARGINAL