AssayIndex

SSA-2501-M6043

MOTS-c · 10 mg declared · Shanghai Sigma-Audley New Material Technology Co., Ltd. · manufactured 15 Jan 2025

CHARACTERISED
Lot code
SSA-2501-M6043
Supplier
SSA — Shanghai Sigma-Audley New Material Technology Co., Ltd.
Compound
MOTS-c
Compound class
Metabolic and mitochondrial peptides
Declared label claim
10mg
Manufacture date
15 Jan 2025
Index quarter
2025-Q1
Independent assays
14
Laboratories involved
Janoshik, PeptideMeter, Medutest, Kestrel, Nordanalyt, VendorInvestigate
Provenance mix
Buyer-sourced ×3 · Supplier-supplied ×9 · Laboratory-retained ×2
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 14
Median purity 97.93% n=14
Spread (max − min) 1.77pp n=14
Standard deviation 0.490pp n=14
96.797.397.998.499.099.6100.2This lot (SSA-2501-M6043)This lot (SSA-2501-M6043): Q1 97.78, median 97.92, Q3 98.38, n=14n=14All MOTS-cAll MOTS-c: Q1 98.40, median 99.18, Q3 99.65, n=112n=112 Purity (% area)
Figure 1. This lot's independent purity results against the whole MOTS-c record set in the index. The vertical line is the index acceptance specification for the metabolic and mitochondrial peptides class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 14

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020537SSA-2501-M6043Janoshik2025-Q198.212.90Supplier-supplied0PASS
AX-2025-020538SSA-2501-M6043PeptideMeter2025-Q197.962.8289.2Buyer-sourced1FAIL
AX-2025-020539SSA-2501-M6043Medutest2025-Q199.112.4292.5Supplier-supplied0PASS
AX-2025-020540SSA-2501-M6043Kestrel2025-Q198.782.48104.9Supplier-supplied0PASS
AX-2025-020541SSA-2501-M6043Nordanalyt2025-Q198.073.64105.8Supplier-supplied0PASS
AX-2025-020542SSA-2501-M6043Medutest2025-Q197.772.1994.0Supplier-supplied0FAIL
AX-2025-020543SSA-2501-M6043Medutest2025-Q198.443.49Supplier-supplied2MARGINAL
AX-2025-020544SSA-2501-M6043Janoshik2025-Q197.342.8588.9Laboratory-retained1FAIL
AX-2025-020545SSA-2501-M6043Janoshik2025-Q197.892.19104.0Supplier-supplied0FAIL
AX-2025-020546SSA-2501-M6043Janoshik2025-Q198.452.7389.1Supplier-supplied1MARGINAL
AX-2025-020547SSA-2501-M6043PeptideMeter2025-Q197.762.58102.2Supplier-supplied0FAIL
AX-2025-020548SSA-2501-M6043VendorInvestigate2025-Q197.462.2190.6Buyer-sourced0FAIL
AX-2025-020549SSA-2501-M6043Janoshik2025-Q197.803.18Buyer-sourced0FAIL
AX-2025-020550SSA-2501-M6043Nordanalyt2025-Q197.893.12Laboratory-retained0FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik598.21, 97.34, 97.89, 98.45, 97.8097.8930min+0.0097.89
PeptideMeter297.96, 97.7697.8628min-0.0597.91
Medutest399.11, 97.77, 98.4498.4425min+0.0898.36
Kestrel198.7898.7815min+0.2498.54
Nordanalyt298.07, 97.8997.9835min+0.0297.96
VendorInvestigate197.4697.4632min-0.1197.57

This lot contributes 15 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)97.9098.21divergence -0.03 pp vs batch median
Total impurities (% area)not stated1.79
Largest single impurity (% area)not stated1.01
Water (%)1.52.90
Counter-ion (%)not stated4.54
Peptide content (%w/w)93.7not determined
Endotoxin (EU/mg)not stated0.33
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
bis-sulfoxide (+32 Da)14 / 141.220.51–1.83
Met1 sulfoxide (+16 Da)14 / 140.260.12–0.49
deamidated (+1 Da)14 / 140.280.13–0.33
des-Met1 (−131 Da)14 / 140.150.06–0.24
Section 7

What this rollup does not establish