Cross-section

Liraglutide by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for Liraglutide, with a class minimum gradient of 25 min, the method is a live explanation.

154 recordsmedian 99.02 %spec 97.5 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik7230minHigh98.74+0.0098.74ADEQUATE
Medutest3025minUnit99.07+0.0898.99ADEQUATE
PeptideMeter2228minHigh99.25-0.0599.30ADEQUATE
Kestrel1215minUnit99.82+0.2499.58BELOW CLASS MINIMUM
VendorInvestigate932minHigh98.69-0.1198.80ADEQUATE
Nordanalyt935minHigh99.23+0.0299.21ADEQUATE
96.296.897.598.298.999.5100.2JanoshikJanoshik: Q1 98.28, median 98.74, Q3 99.30, n=72outlier 96.45outlier 96.59n=72PeptideMeterPeptideMeter: Q1 98.96, median 99.25, Q3 99.59, n=22n=22MedutestMedutest: Q1 98.58, median 99.07, Q3 99.55, n=30outlier 96.70n=30VendorInvestigateVendorInvestigate: Q1 97.61, median 98.69, Q3 98.97, n=9n=9NordanalytNordanalyt: Q1 98.86, median 99.23, Q3 99.44, n=9outlier 96.74n=9KestrelKestrel: Q1 99.66, median 99.82, Q3 99.93, n=12outlier 97.18outlier 99.00n=12 Purity (% area)
Figure. Liraglutide purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.