AssayIndex

WWB-2603-N3120

Semaglutide · 2 mg declared · Wuhan Wansheng Biotechnology Co., Ltd. · manufactured 09 Mar 2026

CHARACTERISED
Lot code
WWB-2603-N3120
Supplier
WWB — Wuhan Wansheng Biotechnology Co., Ltd.
Compound
Semaglutide
Compound class
Incretin analogues and co-agonists
Declared label claim
2mg
Manufacture date
09 Mar 2026
Index quarter
2026-Q2
Independent assays
15
Laboratories involved
Janoshik, Medutest, VendorInvestigate, Nordanalyt, PeptideMeter, Kestrel
Provenance mix
Buyer-sourced ×3 · Supplier-supplied ×12
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 15
Median purity 98.98% n=15
Spread (max − min) 1.94pp n=15
Standard deviation 0.511pp n=15
96.196.897.598.298.899.5100.2This lot (WWB-2603-N3120)This lot (WWB-2603-N3120): Q1 98.69, median 98.98, Q3 99.19, n=15n=15All SemaglutideAll Semaglutide: Q1 98.24, median 98.87, Q3 99.33, n=926outlier 96.37n=926 Purity (% area)
Figure 1. This lot's independent purity results against the whole Semaglutide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 97.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 15

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041283WWB-2603-N3120Janoshik2026-Q298.246.54Supplier-supplied2MARGINAL
AX-2026-041284WWB-2603-N3120Medutest2026-Q299.556.01Supplier-supplied2MARGINAL
AX-2026-041285WWB-2603-N3120Janoshik2026-Q298.677.2196.1Supplier-supplied2MARGINAL
AX-2026-041286WWB-2603-N3120VendorInvestigate2026-Q297.996.6594.7Buyer-sourced2MARGINAL
AX-2026-041287WWB-2603-N3120Nordanalyt2026-Q299.046.47Supplier-supplied2MARGINAL
AX-2026-041288WWB-2603-N3120Janoshik2026-Q299.456.1690.1Supplier-supplied2MARGINAL
AX-2026-041289WWB-2603-N3120PeptideMeter2026-Q298.376.09101.2Supplier-supplied2MARGINAL
AX-2026-041290WWB-2603-N3120Nordanalyt2026-Q298.966.8594.8Supplier-supplied2MARGINAL
AX-2026-041291WWB-2603-N3120Nordanalyt2026-Q299.336.56Supplier-supplied2MARGINAL
AX-2026-041292WWB-2603-N3120PeptideMeter2026-Q298.816.4193.9Supplier-supplied2MARGINAL
AX-2026-041293WWB-2603-N3120VendorInvestigate2026-Q298.705.9097.7Buyer-sourced2MARGINAL
AX-2026-041294WWB-2603-N3120VendorInvestigate2026-Q298.986.20Buyer-sourced3FAIL
AX-2026-041295WWB-2603-N3120PeptideMeter2026-Q299.006.23Supplier-supplied2MARGINAL
AX-2026-041296WWB-2603-N3120Kestrel2026-Q299.936.58103.7Supplier-supplied2MARGINAL
AX-2026-041297WWB-2603-N3120PeptideMeter2026-Q299.056.3996.5Supplier-supplied2MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik398.24, 98.67, 99.4598.6730min+0.0098.67
Medutest199.5599.5525min+0.0899.47
VendorInvestigate397.99, 98.70, 98.9898.7032min-0.1198.81
Nordanalyt399.04, 98.96, 99.3399.0435min+0.0299.02
PeptideMeter498.37, 98.81, 99.00, 99.0598.9128min-0.0598.95
Kestrel199.9399.9315min+0.2499.69

This lot contributes 15 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.4698.24divergence +0.48 pp vs batch median
Total impurities (% area)0.541.76
Largest single impurity (% area)0.220.89
Water (%)4.56.54
Counter-ion (%)5.58.65
Peptide content (%w/w)89.4not determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-AEEA semaglutide (−145 Da)15 / 150.460.04–0.89
[D-Aib8]-diastereomer15 / 150.270.03–0.69
des-His1 truncate (−137 Da)14 / 150.090.04–0.37
C18 diacid mono-ester12 / 150.040.02–0.07
tBu-protected residual (+56 Da)8 / 150.150.10–0.19
semaglutide dimer6 / 150.100.08–0.15
deamidated (Asn→Asp, +1 Da)5 / 150.020.01–0.03
Section 7

What this rollup does not establish