ERP-2603-D7882

Mazdutide · 10 mg declared · Shanghai ERP Biotechnology Co., Ltd. · manufactured 03 Mar 2026

CHARACTERISED
Lot code
ERP-2603-D7882
Supplier
ERP — Shanghai ERP Biotechnology Co., Ltd.
Compound
Mazdutide
Compound class
Incretin analogues and co-agonists
Declared label claim
10mg
Manufacture date
03 Mar 2026
Index quarter
2026-Q2
Independent assays
6
Laboratories involved
PeptideMeter, VendorInvestigate, Janoshik, Nordanalyt
Provenance mix
Buyer-sourced ×2 · Supplier-supplied ×4
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 6
Median purity 97.54% n=6
Spread (max − min) 0.93pp n=6
Standard deviation 0.368pp n=6
96.897.397.998.599.099.6100.2This lot (ERP-2603-D7882)This lot (ERP-2603-D7882): Q1 97.33, median 97.53, Q3 97.86, n=6n=6All MazdutideAll Mazdutide: Q1 97.88, median 98.11, Q3 98.58, n=33outlier 99.93n=33 Purity (% area)
Figure 1. This lot's independent purity results against the whole Mazdutide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 96.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 6

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042559ERP-2603-D7882PeptideMeter2026-Q297.023.3290.5Buyer-sourced2MARGINAL
AX-2026-042560ERP-2603-D7882VendorInvestigate2026-Q297.283.81104.1Buyer-sourced2MARGINAL
AX-2026-042561ERP-2603-D7882PeptideMeter2026-Q297.944.0497.5Supplier-supplied2MARGINAL
AX-2026-042562ERP-2603-D7882Janoshik2026-Q297.464.39102.6Supplier-supplied2MARGINAL
AX-2026-042563ERP-2603-D7882PeptideMeter2026-Q297.953.9291.4Supplier-supplied2MARGINAL
AX-2026-042564ERP-2603-D7882Nordanalyt2026-Q297.614.26Supplier-supplied2MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
PeptideMeter397.02, 97.94, 97.9597.9428min-0.0597.99
VendorInvestigate197.2897.2832min-0.1197.39
Janoshik197.4697.4630min+0.0097.46
Nordanalyt197.6197.6135min+0.0297.59

This lot contributes 6 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)97.9797.02divergence +0.43 pp vs batch median
Total impurities (% area)not stated2.98
Largest single impurity (% area)not stated1.63
Water (%)2.93.32
Counter-ion (%)not stated7.54
Peptide content (%w/w)not stated88.61
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-Aib2 analogue6 / 60.710.27–1.63
[D-Aib2]-diastereomer6 / 60.680.45–0.80
truncated (4-39)6 / 60.790.33–1.25
trifluoroacetyl adduct (+96 Da)6 / 60.160.10–0.20
oxidised Met (+16 Da)6 / 60.110.05–0.17
Section 7

What this rollup does not establish