Cross-section

PEG-MGF by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for PEG-MGF, with a class minimum gradient of 15 min, the method is a live explanation.

35 recordsmedian 97.92 %spec 92.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik1530minHigh98.04+0.0098.04ADEQUATE
PeptideMeter5 n=528minHigh97.54-0.0597.59ADEQUATE
VendorInvestigate4 n=432minHigh96.13-0.1196.24ADEQUATE
Nordanalyt4 n=435minHigh98.22+0.0298.20ADEQUATE
Kestrel4 n=415minUnit97.84+0.2497.61ADEQUATE
Medutest3 n=325minUnit96.04+0.0895.96ADEQUATE
95.395.996.597.197.798.398.9JanoshikJanoshik: Q1 96.78, median 98.04, Q3 98.20, n=15n=15PeptideMeterPeptideMeter: Q1 95.82, median 97.54, Q3 98.23, n=5n=5MedutestMedutest: Q1 95.97, median 96.04, Q3 96.17, n=3n=3VendorInvestigateVendorInvestigate: Q1 96.00, median 96.13, Q3 96.34, n=4outlier 96.87n=4NordanalytNordanalyt: Q1 98.07, median 98.22, Q3 98.37, n=4n=4KestrelKestrel: Q1 97.63, median 97.84, Q3 98.04, n=4n=4 Purity (% area)
Figure. PEG-MGF purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.