ARA-290 by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for ARA-290, with a class minimum gradient of 15 min, the method is a live explanation.

65 recordsmedian 99.45 %spec 98.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik2530minHigh99.42+0.0099.42ADEQUATE
PeptideMeter1228minHigh99.59-0.0599.64ADEQUATE
VendorInvestigate1032minHigh98.75-0.1198.86ADEQUATE
Medutest925minUnit99.81+0.0899.73ADEQUATE
Nordanalyt6 n=635minHigh99.70+0.0299.69ADEQUATE
Kestrel3 n=315minUnit99.74+0.2499.50ADEQUATE
97.898.298.698.999.399.7100.1JanoshikJanoshik: Q1 99.04, median 99.42, Q3 99.93, n=25n=25PeptideMeterPeptideMeter: Q1 98.75, median 99.59, Q3 99.89, n=12n=12MedutestMedutest: Q1 99.37, median 99.81, Q3 99.93, n=9n=9VendorInvestigateVendorInvestigate: Q1 98.47, median 98.75, Q3 99.29, n=10n=10NordanalytNordanalyt: Q1 99.57, median 99.70, Q3 99.91, n=6n=6KestrelKestrel: Q1 99.41, median 99.74, Q3 99.84, n=3n=3 Purity (% area)
Figure. ARA-290 purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.