5-Amino-1MQ by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for 5-Amino-1MQ, with a class minimum gradient of 15 min, the method is a live explanation.

68 recordsmedian 99.24 %spec 98.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik3530minHigh99.27+0.0099.27ADEQUATE
Medutest1125minUnit99.31+0.0899.23ADEQUATE
PeptideMeter6 n=628minHigh99.56-0.0599.61ADEQUATE
Nordanalyt6 n=635minHigh98.97+0.0298.95ADEQUATE
VendorInvestigate5 n=532minHigh98.77-0.1198.88ADEQUATE
Kestrel5 n=515minUnit99.22+0.2498.98ADEQUATE
97.898.298.698.999.399.7100.1JanoshikJanoshik: Q1 98.88, median 99.27, Q3 99.52, n=35n=35PeptideMeterPeptideMeter: Q1 99.29, median 99.56, Q3 99.81, n=6n=6MedutestMedutest: Q1 99.08, median 99.31, Q3 99.66, n=11n=11VendorInvestigateVendorInvestigate: Q1 98.44, median 98.77, Q3 99.24, n=5n=5NordanalytNordanalyt: Q1 98.73, median 98.97, Q3 99.20, n=6n=6KestrelKestrel: Q1 99.10, median 99.22, Q3 99.58, n=5n=5 Purity (% area)
Figure. 5-Amino-1MQ purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.