QSC-2402-U8375

MOTS-c · 10 mg declared · Qingdao Sigma Chemical Co., Ltd. · manufactured 03 Feb 2024

CHARACTERISED
Lot code
QSC-2402-U8375
Supplier
QSC — Qingdao Sigma Chemical Co., Ltd.
Compound
MOTS-c
Compound class
Metabolic and mitochondrial peptides
Declared label claim
10mg
Manufacture date
03 Feb 2024
Index quarter
2024-Q3
Independent assays
13
Laboratories involved
Medutest, Kestrel, PeptideMeter, Janoshik
Provenance mix
Supplier-supplied ×10 · Laboratory-retained ×3
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 13
Median purity 99.93% n=13
Spread (max − min) 0.51pp n=13
Standard deviation 0.208pp n=13
96.797.397.998.499.099.6100.2This lot (QSC-2402-U8375)This lot (QSC-2402-U8375): Q1 99.65, median 99.93, Q3 99.93, n=13n=13All MOTS-cAll MOTS-c: Q1 98.40, median 99.18, Q3 99.65, n=112n=112 Purity (% area)
Figure 1. This lot's independent purity results against the whole MOTS-c record set in the index. The vertical line is the index acceptance specification for the metabolic and mitochondrial peptides class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 13

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004390QSC-2402-U8375Medutest2024-Q399.933.3388.8Supplier-supplied1MARGINAL
AX-2024-004391QSC-2402-U8375Kestrel2024-Q399.933.49Supplier-supplied1MARGINAL
AX-2024-004392QSC-2402-U8375Kestrel2024-Q399.933.25102.8Laboratory-retained0PASS
AX-2024-004393QSC-2402-U8375PeptideMeter2024-Q399.453.06Supplier-supplied0PASS
AX-2024-004394QSC-2402-U8375PeptideMeter2024-Q399.933.49103.4Supplier-supplied0PASS
AX-2024-004395QSC-2402-U8375PeptideMeter2024-Q399.422.9893.8Laboratory-retained0PASS
AX-2024-004396QSC-2402-U8375PeptideMeter2024-Q399.653.2596.5Laboratory-retained0PASS
AX-2024-004397QSC-2402-U8375Janoshik2024-Q399.933.1997.5Supplier-supplied0PASS
AX-2024-004398QSC-2402-U8375PeptideMeter2024-Q399.932.95Supplier-supplied0PASS
AX-2024-004399QSC-2402-U8375Janoshik2024-Q399.933.40Supplier-supplied0PASS
AX-2024-004400QSC-2402-U8375Medutest2024-Q399.523.3591.4Supplier-supplied2MARGINAL
AX-2024-004401QSC-2402-U8375Kestrel2024-Q399.932.68106.6Supplier-supplied1MARGINAL
AX-2024-004402QSC-2402-U8375Janoshik2024-Q399.933.7099.6Supplier-supplied1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest299.93, 99.5299.7225min+0.0899.64
Kestrel399.93, 99.93, 99.9399.9315min+0.2499.69
PeptideMeter599.45, 99.93, 99.42, 99.65, 99.9399.6528min-0.0599.70
Janoshik399.93, 99.93, 99.9399.9330min+0.0099.93

This lot contributes 6 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence -0.03 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.070.04
Water (%)not stated3.33
Counter-ion (%)not stated3.65
Peptide content (%w/w)not stated92.52
Endotoxin (EU/mg)0.27not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-Met1 (−131 Da)13 / 130.030.03–0.15
deamidated (+1 Da)9 / 130.040.04–0.26
Met1 sulfoxide (+16 Da)8 / 130.040.04–0.23
bis-sulfoxide (+32 Da)4 / 130.090.05–0.13
Section 7

What this rollup does not establish