AssayIndex

QSC-2402-G9476

Melanotan II · 10 mg declared · Qingdao Sigma Chemical Co., Ltd. · manufactured 12 Feb 2024

SINGLE TEST
Lot code
QSC-2402-G9476
Supplier
QSC — Qingdao Sigma Chemical Co., Ltd.
Compound
Melanotan II
Compound class
Melanocortin-receptor peptides
Declared label claim
10mg
Manufacture date
12 Feb 2024
Index quarter
2024-Q3
Independent assays
1
Laboratories involved
Janoshik
Provenance mix
Supplier-supplied ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 99.93% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
96.697.297.898.499.099.6100.2All Melanotan IIAll Melanotan II: Q1 98.80, median 99.24, Q3 99.69, n=186outlier 96.85n=186 Purity (% area)
Figure 1. This lot's independent purity results against the whole Melanotan II record set in the index. The vertical line is the index acceptance specification for the melanocortin-receptor peptides class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-004431QSC-2402-G9476Janoshik2024-Q399.932.48Supplier-supplied1FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik199.9399.9330min+0.0099.93

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.93divergence -0.03 pp vs batch median
Total impurities (% area)0.100.07
Largest single impurity (% area)0.060.04
Water (%)not stated2.48
Counter-ion (%)5.65.02
Peptide content (%w/w)90.3not determined
Endotoxin (EU/mg)not stated5.99
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-acetyl MT-II (−42 Da)1 / 10.04
linear (open-lactam) precursor (+18 Da)1 / 10.03
Section 7

What this rollup does not establish