AssayIndex

GGPE-2603-R2320

Cagrilintide · 2 mg declared · Nantong Guangyuan Chemical Co., Ltd. · manufactured 27 Mar 2026

SINGLE TEST
Lot code
GGPE-2603-R2320
Supplier
GGPeps — Nantong Guangyuan Chemical Co., Ltd.
Compound
Cagrilintide
Compound class
Incretin analogues and co-agonists
Declared label claim
2mg
Manufacture date
27 Mar 2026
Index quarter
2026-Q2
Independent assays
1
Laboratories involved
Medutest
Provenance mix
Supplier-supplied ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 98.13% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
97.297.798.298.799.199.6100.1All CagrilintideAll Cagrilintide: Q1 98.25, median 98.69, Q3 99.23, n=54n=54 Purity (% area)
Figure 1. This lot's independent purity results against the whole Cagrilintide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 96.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042863GGPE-2603-R2320Medutest2026-Q298.136.4688.7Supplier-supplied1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest198.1398.1325min+0.0898.05

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.6798.13divergence +0.54 pp vs batch median
Total impurities (% area)1.331.87
Largest single impurity (% area)0.850.81
Water (%)4.56.46
Counter-ion (%)not stated9.03
Peptide content (%w/w)not stated83.68
Endotoxin (EU/mg)0.53not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
open-chain (reduced disulfide, +2 Da)1 / 10.81
deamidated (+1 Da)1 / 10.56
disulfide-scrambled isomer1 / 10.23
des-C16 diacid (−254 Da)1 / 10.14
cagrilintide dimer (intermolecular disulfide)1 / 10.13
Section 7

What this rollup does not establish