AssayIndex

GSP-2411-L1648

AOD-9604 · 2 mg declared · GenScript Biotech Corporation · manufactured 10 Nov 2024

CHARACTERISED
Lot code
GSP-2411-L1648
Supplier
GSP — GenScript Biotech Corporation
Compound
AOD-9604
Compound class
Metabolic and mitochondrial peptides
Declared label claim
2mg
Manufacture date
10 Nov 2024
Index quarter
2025-Q2
Independent assays
4
Laboratories involved
Janoshik, Nordanalyt
Provenance mix
Buyer-sourced ×3 · Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 4
Median purity 99.13% n=4
Spread (max − min) 0.54pp n=4
Standard deviation 0.221pp n=4
97.698.098.498.899.399.7100.1This lot (GSP-2411-L1648)This lot (GSP-2411-L1648): Q1 99.07, median 99.13, Q3 99.20, n=4outlier 99.43n=4All AOD-9604All AOD-9604: Q1 98.88, median 99.30, Q3 99.72, n=99n=99 Purity (% area)
Figure 1. This lot's independent purity results against the whole AOD-9604 record set in the index. The vertical line is the index acceptance specification for the metabolic and mitochondrial peptides class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 4

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-018985GSP-2411-L1648Janoshik2025-Q299.435.00Buyer-sourced0PASS
AX-2025-018986GSP-2411-L1648Nordanalyt2025-Q299.134.59Buyer-sourced0PASS
AX-2025-018987GSP-2411-L1648Janoshik2025-Q299.135.23102.1Buyer-sourced0PASS
AX-2025-018988GSP-2411-L1648Janoshik2025-Q298.895.21Laboratory-retained0PASS
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik399.43, 99.13, 98.8999.1330min+0.0099.13
Nordanalyt199.1399.1335min+0.0299.11

This lot contributes 1 paired comparison to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.3099.43divergence -0.83 pp vs batch median
Total impurities (% area)1.700.57
Largest single impurity (% area)not stated0.30
Water (%)3.15.00
Counter-ion (%)5.95.19
Peptide content (%w/w)90.4not determined
Endotoxin (EU/mg)0.66not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
open-chain (reduced disulfide, +2 Da)4 / 40.430.30–0.50
Met sulfoxide (+16 Da)4 / 40.170.14–0.25
des-Tyr AOD (−163 Da)4 / 40.160.07–0.28
AOD dimer4 / 40.090.04–0.16
Section 7

What this rollup does not establish