AssayIndex
Submitter and annotator

underfill_3to1

Gravimetric fill checks. Under-fill outnumbers over-fill three to one.

first seen 2025-Q111 records submitted4 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 11 n=11
Annotations 4 n=4
Median purity submitted 99.10% n=11
Suppliers covered 7 n=11
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-041337SemaglutideWWBWWB-2606-N3192Nordanalyt2026-Q398.964.81Supplier-supplied1MARGINAL
AX-2026-041523RetatrutideQYBQYB-2602-R6263Janoshik2026-Q299.105.5190.7Supplier-supplied2MARGINAL
AX-2026-042118PT-141 (Bremelanotide)TFCTFC-2512-M8211Janoshik2026-Q299.137.21101.1Supplier-supplied1MARGINAL
AX-2026-043182PT-141 (Bremelanotide)GL BiochemGLBI-2511-F8417Medutest2026-Q297.572.3693.0Supplier-supplied2FAIL
AX-2026-042494Melanotan IISWBSWB-2602-J6019Janoshik2026-Q199.754.6296.8Laboratory-retained0PASS
AX-2026-042447MGFSWBSWB-2601-E6319Janoshik2026-Q198.965.15106.9Supplier-supplied0PASS
AX-2026-0415425-Amino-1MQQYBQYB-2510-C6129Janoshik2026-Q199.433.5199.5Supplier-supplied1FAIL
AX-2025-019639SemaglutideHomopeptideHOMO-2508-K2535PeptideMeter2025-Q499.643.93Supplier-supplied2MARGINAL
AX-2025-019272SurvodutideTFCTFC-2409-Y6260PeptideMeter2025-Q199.115.9591.9Supplier-supplied1MARGINAL
AX-2024-004376RetatrutideQSCQSC-2404-P8297Janoshik2024-Q298.616.53Supplier-supplied3MARGINAL
AX-2024-004662TirzepatideTFCTFC-2312-P7493Janoshik2024-Q298.513.0488.9Supplier-supplied2MARGINAL
SupplierRecordsMedian purity
TFC399.11
QYB2n<3
SWB2n<3
WWB1n<3
GL Biochem1n<3
Homopeptide1n<3
QSC1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it.

AX-2026-041705
7.28 EU/mg from an older lot. Endotoxins are heat-stable and drift is rare. If this matches fresh-lot median from the same supplier, the number is stable.
AX-2025-018595
Endotoxin tested twice on this lot with varying EU/mg spread. Endotoxin variability in retained samples is larger than most labs acknowledge and the single measurement here is not definitive.
AX-2024-004269
7.46 EU/mg is at the sensitivity limit of Janoshik's LAL method. The true value is unspecified; treating this as a point estimate is overstating precision.
AX-2024-004557
5.20 EU/mg is elevated relative to the index median and the record shows no depyrogenation step. If this material will be reconstituted in aqueous buffer for any downstream use, that endotoxin load is a risk.