AssayIndex
Cross-section

GHK-Cu by laboratory

The same compound measured by different laboratories on different gradients. Where the medians differ, the question is whether the material differed or the method did — and for GHK-Cu, with a class minimum gradient of 15 min, the method is a live explanation.

41 recordsmedian 98.54 %spec 97.0 %
LaboratoryReportsGradientMS resolutionMedian purity %Published bias (pp)Bias-adjustedMethod suitability
Janoshik1930minHigh98.45+0.0098.45ADEQUATE
PeptideMeter828minHigh98.99-0.0599.04ADEQUATE
Medutest6 n=625minUnit98.96+0.0898.88ADEQUATE
VendorInvestigate3 n=332minHigh98.35-0.1198.46ADEQUATE
Kestrel3 n=315minUnit98.86+0.2498.62ADEQUATE
Nordanalyt2 n=235minHigh98.41, 98.98+0.02ADEQUATE
96.497.097.798.398.999.6100.2JanoshikJanoshik: Q1 97.56, median 98.45, Q3 98.64, n=19n=19PeptideMeterPeptideMeter: Q1 98.69, median 98.99, Q3 99.34, n=8n=8MedutestMedutest: Q1 98.75, median 98.96, Q3 99.20, n=6n=6VendorInvestigateVendorInvestigate: Q1 98.12, median 98.35, Q3 98.52, n=3n=3NordanalytNordanalyt: Q1 98.55, median 98.69, Q3 98.84, n=2n=2KestrelKestrel: Q1 98.63, median 98.86, Q3 99.40, n=3n=3 Purity (% area)
Figure. GHK-Cu purity by contributing laboratory. Any offset between rows has two possible sources — a real difference in the material each laboratory happened to receive, and the laboratory's own bias — and this figure cannot separate them. The paired analysis that can is on inter-lab agreement.