AssayIndex

WXT-2604-K4483

Leuprolide · 5 mg declared · WuXi TIDES (WuXi AppTec Testing Division) · manufactured 24 Apr 2026

CHARACTERISED
Lot code
WXT-2604-K4483
Supplier
WXT — WuXi TIDES (WuXi AppTec Testing Division)
Compound
Leuprolide
Compound class
Hypothalamic and posterior-pituitary hormones
Declared label claim
5mg
Manufacture date
24 Apr 2026
Index quarter
2026-Q3
Independent assays
13
Laboratories involved
Janoshik, Medutest, PeptideMeter, Nordanalyt, VendorInvestigate
Provenance mix
Buyer-sourced ×8 · Supplier-supplied ×5
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 13
Median purity 99.00% n=13
Spread (max − min) 1.35pp n=13
Standard deviation 0.434pp n=13
98.498.799.099.299.599.7100.0This lot (WXT-2604-K4483)This lot (WXT-2604-K4483): Q1 98.78, median 99.00, Q3 99.27, n=13n=13All LeuprolideAll Leuprolide: Q1 98.81, median 99.23, Q3 99.61, n=18n=18 Purity (% area)
Figure 1. This lot's independent purity results against the whole Leuprolide record set in the index. The vertical line is the index acceptance specification for the hypothalamic and posterior-pituitary hormones class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 13

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043530WXT-2604-K4483Janoshik2026-Q398.564.98104.6Buyer-sourced0PASS
AX-2026-043531WXT-2604-K4483Medutest2026-Q399.005.03Buyer-sourced0PASS
AX-2026-043532WXT-2604-K4483Medutest2026-Q399.275.30Supplier-supplied0PASS
AX-2026-043533WXT-2604-K4483PeptideMeter2026-Q399.894.94Supplier-supplied0PASS
AX-2026-043534WXT-2604-K4483Janoshik2026-Q398.865.7791.3Buyer-sourced1MARGINAL
AX-2026-043535WXT-2604-K4483Janoshik2026-Q399.474.86Supplier-supplied0PASS
AX-2026-043536WXT-2604-K4483Janoshik2026-Q399.225.66Supplier-supplied0PASS
AX-2026-043537WXT-2604-K4483PeptideMeter2026-Q399.706.0398.4Supplier-supplied0PASS
AX-2026-043538WXT-2604-K4483Medutest2026-Q399.245.50104.2Buyer-sourced0PASS
AX-2026-043539WXT-2604-K4483Nordanalyt2026-Q398.785.31Buyer-sourced0PASS
AX-2026-043540WXT-2604-K4483VendorInvestigate2026-Q398.585.5794.9Buyer-sourced0PASS
AX-2026-043541WXT-2604-K4483Janoshik2026-Q398.925.40Buyer-sourced0PASS
AX-2026-043542WXT-2604-K4483Medutest2026-Q398.545.0496.2Buyer-sourced0PASS
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik598.56, 98.86, 99.47, 99.22, 98.9298.9230min+0.0098.92
Medutest499.00, 99.27, 99.24, 98.5499.1225min+0.0899.04
PeptideMeter299.89, 99.7099.8028min-0.0599.84
Nordanalyt198.7898.7835min+0.0298.76
VendorInvestigate198.5898.5832min-0.1198.69

This lot contributes 10 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.2598.56divergence +0.25 pp vs batch median
Total impurities (% area)not stated1.44
Largest single impurity (% area)not stated0.52
Water (%)4.64.98
Counter-ion (%)7.15.36
Peptide content (%w/w)87.789.32
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
[L-Leu6]-diastereomer13 / 130.220.04–0.42
oxidised Trp (+16 Da)13 / 130.310.05–0.81
des-ethylamide (+1 Da)13 / 130.100.02–0.19
ring-opened pGlu (+18 Da)12 / 130.270.01–0.53
Section 7

What this rollup does not establish