AssayIndex

KP-2605-E6030

Tirzepatide · 15 mg declared · Zhuhai Kerui Biotechnology Co., Ltd. · manufactured 12 May 2026

CHARACTERISED
Lot code
KP-2605-E6030
Supplier
KP — Zhuhai Kerui Biotechnology Co., Ltd.
Compound
Tirzepatide
Compound class
Incretin analogues and co-agonists
Declared label claim
15mg
Manufacture date
12 May 2026
Index quarter
2026-Q2
Independent assays
14
Laboratories involved
VendorInvestigate, Janoshik, PeptideMeter, Kestrel, Medutest
Provenance mix
Buyer-sourced ×7 · Supplier-supplied ×6 · Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 14
Median purity 97.53% n=14
Spread (max − min) 1.86pp n=14
Standard deviation 0.473pp n=14
95.696.497.197.998.799.5100.3This lot (KP-2605-E6030)This lot (KP-2605-E6030): Q1 97.40, median 97.53, Q3 97.68, n=14outlier 98.25outlier 98.91n=14All TirzepatideAll Tirzepatide: Q1 97.85, median 98.44, Q3 99.08, n=576outlier 95.92n=576 Purity (% area)
Figure 1. This lot's independent purity results against the whole Tirzepatide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 97.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 14

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043072KP-2605-E6030VendorInvestigate2026-Q297.183.6996.7Buyer-sourced1MARGINAL
AX-2026-043073KP-2605-E6030Janoshik2026-Q297.684.22Supplier-supplied1MARGINAL
AX-2026-043074KP-2605-E6030VendorInvestigate2026-Q297.404.6691.4Buyer-sourced1MARGINAL
AX-2026-043075KP-2605-E6030VendorInvestigate2026-Q297.214.07Buyer-sourced1MARGINAL
AX-2026-043076KP-2605-E6030Janoshik2026-Q297.683.59104.0Supplier-supplied1MARGINAL
AX-2026-043077KP-2605-E6030VendorInvestigate2026-Q297.443.5791.6Buyer-sourced1MARGINAL
AX-2026-043078KP-2605-E6030PeptideMeter2026-Q297.515.1190.6Supplier-supplied1MARGINAL
AX-2026-043079KP-2605-E6030Kestrel2026-Q298.914.1889.6Supplier-supplied3MARGINAL
AX-2026-043080KP-2605-E6030VendorInvestigate2026-Q297.054.22Buyer-sourced1MARGINAL
AX-2026-043081KP-2605-E6030VendorInvestigate2026-Q297.554.2191.4Laboratory-retained1MARGINAL
AX-2026-043082KP-2605-E6030Medutest2026-Q298.254.08103.5Supplier-supplied1MARGINAL
AX-2026-043083KP-2605-E6030VendorInvestigate2026-Q297.543.89Buyer-sourced1MARGINAL
AX-2026-043084KP-2605-E6030Janoshik2026-Q297.403.52Supplier-supplied1MARGINAL
AX-2026-043085KP-2605-E6030Janoshik2026-Q297.714.30Buyer-sourced1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
VendorInvestigate797.18, 97.40, 97.21, 97.44, 97.05, 97.55, 97.5497.4032min-0.1197.51
Janoshik497.68, 97.68, 97.40, 97.7197.6830min+0.0097.68
PeptideMeter197.5197.5128min-0.0597.56
Kestrel198.9198.9115min+0.2498.67
Medutest198.2598.2525min+0.0898.17

This lot contributes 10 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.3597.18divergence +0.82 pp vs batch median
Total impurities (% area)1.652.82
Largest single impurity (% area)not stated1.20
Water (%)2.73.69
Counter-ion (%)not stated7.66
Peptide content (%w/w)not stated87.99
Endotoxin (EU/mg)not stated1.26
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
trifluoroacetyl adduct (+96 Da)14 / 140.400.05–1.25
[D-Aib13]-diastereomer14 / 140.890.28–1.12
des-Aib2 analogue14 / 140.340.11–1.24
Met(O) sulfoxide (+16 Da)14 / 140.060.04–0.15
tirzepatide dimer7 / 140.250.17–0.28
des-Gly deletion (−57 Da)7 / 140.050.03–0.06
C20 diacid mono-amide7 / 140.280.19–0.32
truncated (3-39)6 / 140.040.04–0.04
Section 7

What this rollup does not establish