AssayIndex

GGPE-2605-B9821

BPC-157 · 5 mg declared · Nantong Guangyuan Chemical Co., Ltd. · manufactured 21 May 2026

CHARACTERISED
Lot code
GGPE-2605-B9821
Supplier
GGPeps — Nantong Guangyuan Chemical Co., Ltd.
Compound
BPC-157
Compound class
Tissue-repair and immunomodulatory peptides
Declared label claim
5mg
Manufacture date
21 May 2026
Index quarter
2026-Q2
Independent assays
3
Laboratories involved
Medutest, VendorInvestigate, Janoshik
Provenance mix
Buyer-sourced ×1 · Supplier-supplied ×2
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 3
Median purity 98.76% n=3
Spread (max − min) 1.06pp n=3
Standard deviation 0.578pp n=3
96.897.397.998.599.099.6100.2This lot (GGPE-2605-B9821)This lot (GGPE-2605-B9821): Q1 98.30, median 98.76, Q3 98.83, n=3n=3All BPC-157All BPC-157: Q1 98.59, median 99.15, Q3 99.71, n=591n=591 Purity (% area)
Figure 1. This lot's independent purity results against the whole BPC-157 record set in the index. The vertical line is the index acceptance specification for the tissue-repair and immunomodulatory peptides class, 98.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 3

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042762GGPE-2605-B9821Medutest2026-Q298.894.33Supplier-supplied2MARGINAL
AX-2026-042763GGPE-2605-B9821VendorInvestigate2026-Q297.833.92106.0Buyer-sourced1FAIL
AX-2026-042764GGPE-2605-B9821Janoshik2026-Q298.764.99Supplier-supplied3MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest198.8998.8925min+0.0898.81
VendorInvestigate197.8397.8332min-0.1197.94
Janoshik198.7698.7630min+0.0098.76

This lot contributes 3 paired comparisons to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.7998.89divergence +0.03 pp vs batch median
Total impurities (% area)1.211.11
Largest single impurity (% area)0.570.68
Water (%)3.24.33
Counter-ion (%)not stated8.71
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)0.43not determined
Method stated on certificateNOno method section — the result cannot be reconciled against any other
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-Gly truncate (−57 Da)3 / 30.840.68–1.02
[D-Val]-diastereomer3 / 30.220.20–0.29
truncated (1-12)3 / 30.080.08–0.08
acetylated N-terminus (+42 Da)3 / 30.060.03–0.07
pyroglutamate cyclisation (−17 Da)3 / 30.030.02–0.24
BPC-157 arginine-salt artefact2 / 30.290.01–0.57
Section 7

What this rollup does not establish