AssayIndex

GGPE-2511-X1174

Semax · 20 mg declared · Nantong Guangyuan Chemical Co., Ltd. · manufactured 25 Nov 2025

SINGLE TESTSHARED BULK
Lot code
GGPE-2511-X1174
Supplier
GGPeps — Nantong Guangyuan Chemical Co., Ltd.
Compound
Semax
Compound class
Neuroactive and cognitive peptides
Declared label claim
20mg
Manufacture date
25 Nov 2025
Index quarter
2026-Q1
Independent assays
1
Laboratories involved
Medutest
Provenance mix
Buyer-sourced ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 99.59% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
97.397.898.398.799.299.7100.1All SemaxAll Semax: Q1 98.97, median 99.46, Q3 99.74, n=216outlier 97.54n=216 Purity (% area)
Figure 1. This lot's independent purity results against the whole Semax record set in the index. The vertical line is the index acceptance specification for the neuroactive and cognitive peptides class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042741GGPE-2511-X1174Medutest2026-Q199.596.9497.2Buyer-sourced1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest199.5999.5925min+0.0899.51

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.4599.59divergence -0.14 pp vs batch median
Total impurities (% area)0.550.41
Largest single impurity (% area)not stated0.26
Water (%)not stated6.94
Counter-ion (%)not stated5.57
Peptide content (%w/w)91.787.24
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
diketopiperazine (−18 Da)1 / 10.26
N-acetyl semax (+42 Da)1 / 10.08
Met1 sulfoxide (+16 Da)1 / 10.05
des-Met (−131 Da)1 / 10.02
Section 6

Shared-bulk links

Rule AX-R09. Where impurity fingerprints and latent composition match across companies, the index treats the material as one bulk and counts it once in aggregates.

LotSold byRoleReportsMedian purity
SNP-2601-U4736SinoPepparent bulk1099.52
GGPE-2511-X1174GGPepsthis lot199.59
Section 7

What this rollup does not establish