AssayIndex

ERP-2605-E9273

Survodutide · 5 mg declared · Shanghai ERP Biotechnology Co., Ltd. · manufactured 11 May 2026

SINGLE TESTSHARED BULK
Lot code
ERP-2605-E9273
Supplier
ERP — Shanghai ERP Biotechnology Co., Ltd.
Compound
Survodutide
Compound class
Incretin analogues and co-agonists
Declared label claim
5mg
Manufacture date
11 May 2026
Index quarter
2026-Q3
Independent assays
1
Laboratories involved
Janoshik
Provenance mix
Buyer-sourced ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 98.69% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
96.997.498.098.599.199.6100.2All SurvodutideAll Survodutide: Q1 98.00, median 98.60, Q3 98.94, n=79n=79 Purity (% area)
Figure 1. This lot's independent purity results against the whole Survodutide record set in the index. The vertical line is the index acceptance specification for the incretin analogues and co-agonists class, 96.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042756ERP-2605-E9273Janoshik2026-Q398.695.74Buyer-sourced1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Janoshik198.6998.6930min+0.0098.69

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.3098.69divergence -0.39 pp vs batch median
Total impurities (% area)not stated1.31
Largest single impurity (% area)not stated0.66
Water (%)3.65.74
Counter-ion (%)not stated6.48
Peptide content (%w/w)96.3not determined
Endotoxin (EU/mg)1.55not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-γGlu linker (−129 Da)1 / 10.66
[D-Ser2]-diastereomer1 / 10.30
truncated (2-39)1 / 10.24
aspartimide (−18 Da)1 / 10.05
survodutide dimer1 / 10.04
C18 diacid mono-ester1 / 10.02
Section 6

Shared-bulk links

Rule AX-R09. Where impurity fingerprints and latent composition match across companies, the index treats the material as one bulk and counts it once in aggregates.

LotSold byRoleReportsMedian purity
HYB-2504-X5304HYBparent bulk1498.75
ERP-2605-E9273ERPthis lot198.69
Section 7

What this rollup does not establish