AssayIndex
Submitter and annotator

shared_bulk

Impurity fingerprinting to identify lots that are the same material under two labels.

first seen 2024-Q411 records submitted1 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 11 n=11
Annotations 1 n=1
Median purity submitted 98.87% n=11
Suppliers covered 8 n=11
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042701SemaglutideGGPepsGGPE-2604-L9412VendorInvestigate2026-Q298.345.6692.1Buyer-sourced0PASS
AX-2026-043521MK-677 (Ibutamoren mesylate)BCHBCH-2511-G7276Medutest2026-Q298.434.78Supplier-supplied2FAIL
AX-2026-042892SemaglutideMKMMKM-2510-S2813Medutest2026-Q199.496.5193.0Supplier-supplied1MARGINAL
AX-2026-043553MK-677 (Ibutamoren mesylate)BCHBCH-2601-G7069Nordanalyt2026-Q198.013.91Supplier-supplied1FAIL
AX-2025-020768SemaglutideSGNSGN-2502-F9601Janoshik2025-Q399.135.75Supplier-supplied1MARGINAL
AX-2025-019980SemaglutideERPERP-2508-S6110Janoshik2025-Q399.253.2990.3Supplier-supplied1MARGINAL
AX-2025-019746TirzepatideHJHJ-2502-P3591VendorInvestigate2025-Q198.722.7398.3Buyer-sourced1MARGINAL
AX-2025-018985DihexaFGPFGP-2408-S1457Medutest2025-Q199.496.75Supplier-supplied1MARGINAL
AX-2024-004873NAD+SWBSWB-2405-L5945Medutest2024-Q398.879.49105.2Supplier-supplied1FAIL
AX-2024-004491SermorelinFGPFGP-2406-D1606Janoshik2024-Q399.633.43Supplier-supplied0PASS
AX-2024-005532SemaglutideBCHBCH-2401-C7932Janoshik2024-Q298.095.79Laboratory-retained2MARGINAL
SupplierRecordsMedian purity
BCH398.09
FGP2n<3
GGPeps1n<3
MKM1n<3
SGN1n<3
ERP1n<3
HJ1n<3
SWB1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it.

AX-2026-041708
Purity 99.57 % and endotoxin 5.66 EU/mg are unrelated — purity measures synthesis quality, endotoxin measures fill-step water quality. The combination here is coherent and expected together.