SIG-2511-5466

Ipamorelin · 5 mg declared · Sigma-Aldrich (Shanghai) Trading Co., Ltd. · manufactured 24 Nov 2025

PARTIALLY CHARACTERISED
Lot code
SIG-2511-5466
Supplier
SIG — Sigma-Aldrich (Shanghai) Trading Co., Ltd.
Compound
Ipamorelin
Compound class
Growth-hormone axis peptides
Declared label claim
5mg
Manufacture date
24 Nov 2025
Index quarter
2026-Q2
Independent assays
2
Laboratories involved
Kestrel, VendorInvestigate
Provenance mix
Buyer-sourced ×2
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 2
Median purity 99.36% n=2
Spread (max − min) 0.75pp n=2
Standard deviation n<3 n=2
97.798.198.598.999.399.7100.1This lot (SIG-2511-5466)This lot (SIG-2511-5466): Q1 99.17, median 99.36, Q3 99.54, n=2n=2All IpamorelinAll Ipamorelin: Q1 99.01, median 99.47, Q3 99.80, n=204n=204 Purity (% area)
Figure 1. This lot's independent purity results against the whole Ipamorelin record set in the index. The vertical line is the index acceptance specification for the growth-hormone axis peptides class, 99.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 2

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043499SIG-2511-5466Kestrel2026-Q299.734.5699.3Buyer-sourced1MARGINAL
AX-2026-043500SIG-2511-5466VendorInvestigate2026-Q298.984.50Buyer-sourced1FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Kestrel199.7399.7315min+0.2499.49
VendorInvestigate198.9898.9832min-0.1199.09

This lot contributes 1 paired comparison to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.7799.73divergence +0.41 pp vs batch median
Total impurities (% area)0.090.27
Largest single impurity (% area)0.230.16
Water (%)not stated4.56
Counter-ion (%)not stated7.32
Peptide content (%w/w)91.787.82
Endotoxin (EU/mg)0.300.80
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
oxidised Trp (+16 Da)2 / 20.380.16–0.60
[D-Trp]-epimer2 / 20.080.07–0.09
C-terminal free acid (+1 Da)2 / 20.030.02–0.04
des-Lys (−128 Da)2 / 20.130.02–0.23
Aib-deletion sequence (−85 Da)1 / 20.06
Section 7

What this rollup does not establish