AssayIndex

MKM-2508-S3601

MGF · 5 mg declared · Xi'an Mokemei Biotechnology Co., Ltd. · manufactured 25 Aug 2025

CHARACTERISED
Lot code
MKM-2508-S3601
Supplier
MKM — Xi'an Mokemei Biotechnology Co., Ltd.
Compound
MGF
Compound class
Growth-hormone axis peptides
Declared label claim
5mg
Manufacture date
25 Aug 2025
Index quarter
2025-Q3
Independent assays
3
Laboratories involved
Medutest, Janoshik
Provenance mix
Supplier-supplied ×3
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 3
Median purity 98.30% n=3
Spread (max − min) 0.30pp n=3
Standard deviation 0.153pp n=3
97.597.998.398.799.199.599.9This lot (MKM-2508-S3601)This lot (MKM-2508-S3601): Q1 98.25, median 98.30, Q3 98.40, n=3n=3All MGFAll MGF: Q1 98.39, median 98.73, Q3 99.03, n=32n=32 Purity (% area)
Figure 1. This lot's independent purity results against the whole MGF record set in the index. The vertical line is the index acceptance specification for the growth-hormone axis peptides class, 97.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 3

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2025-020384MKM-2508-S3601Medutest2025-Q398.303.2591.9Supplier-supplied1FAIL
AX-2025-020385MKM-2508-S3601Janoshik2025-Q398.503.6798.9Supplier-supplied1MARGINAL
AX-2025-020386MKM-2508-S3601Janoshik2025-Q398.203.50Supplier-supplied1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest198.3098.3025min+0.0898.22
Janoshik298.50, 98.2098.3530min+0.0098.35

This lot contributes 1 paired comparison to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)98.2798.30divergence -0.03 pp vs batch median
Total impurities (% area)1.731.70
Largest single impurity (% area)0.610.71
Water (%)not stated3.25
Counter-ion (%)not stated6.37
Peptide content (%w/w)not stated89.77
Endotoxin (EU/mg)0.630.75
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
acetyl adduct (+42 Da)3 / 30.710.08–0.75
deamidated (+1 Da)3 / 30.690.65–1.06
aspartimide (−18 Da)3 / 30.200.19–0.29
truncated (1-20)3 / 30.150.07–0.16
Section 7

What this rollup does not establish