AssayIndex

HOMO-2605-S1342

Semax · 20 mg declared · Hunan Aslsen Technology Co., Ltd. · manufactured 26 May 2026

SINGLE TEST
Lot code
HOMO-2605-S1342
Supplier
Homopeptide — Hunan Aslsen Technology Co., Ltd.
Compound
Semax
Compound class
Neuroactive and cognitive peptides
Declared label claim
20mg
Manufacture date
26 May 2026
Index quarter
2026-Q3
Independent assays
1
Laboratories involved
Medutest
Provenance mix
Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 99.44% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
97.698.098.598.999.399.7100.1All SemaxAll Semax: Q1 98.65, median 99.17, Q3 99.63, n=160n=160 Purity (% area)
Figure 1. This lot's independent purity results against the whole Semax record set in the index. The vertical line is the index acceptance specification for the neuroactive and cognitive peptides class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042260HOMO-2605-S1342Medutest2026-Q399.446.0692.4Laboratory-retained1FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest199.4499.4425min+0.0899.36

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.9099.44divergence +0.46 pp vs batch median
Total impurities (% area)0.100.56
Largest single impurity (% area)0.060.37
Water (%)3.96.06
Counter-ion (%)not stated4.98
Peptide content (%w/w)not stated88.64
Endotoxin (EU/mg)0.430.66
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
Met1 sulfoxide (+16 Da)1 / 10.37
diketopiperazine (−18 Da)1 / 10.12
N-acetyl semax (+42 Da)1 / 10.04
des-Met (−131 Da)1 / 10.03