AssayIndex

GLBI-2606-S7352

L-Glutathione (reduced) · 600 mg declared · GL Biochem (Shanghai) Ltd. · manufactured 03 Jun 2026

PARTIALLY CHARACTERISEDSHARED BULK
Lot code
GLBI-2606-S7352
Supplier
GL Biochem — GL Biochem (Shanghai) Ltd.
Compound
L-Glutathione (reduced)
Compound class
Short bioregulator peptides
Declared label claim
600mg
Manufacture date
03 Jun 2026
Index quarter
2026-Q3
Independent assays
2
Laboratories involved
Medutest, Janoshik
Provenance mix
Supplier-supplied ×1 · Laboratory-retained ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 2
Median purity 99.24% n=2
Spread (max − min) 0.46pp n=2
Standard deviation n<3 n=2
97.297.798.298.799.299.6100.1This lot (GLBI-2606-S7352)This lot (GLBI-2606-S7352): Q1 99.13, median 99.24, Q3 99.36, n=2n=2All L-Glutathione (reduced)All L-Glutathione (reduced): Q1 98.59, median 99.33, Q3 99.66, n=129n=129 Purity (% area)
Figure 1. This lot's independent purity results against the whole L-Glutathione (reduced) record set in the index. The vertical line is the index acceptance specification for the short bioregulator peptides class, 98.5 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 2

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-043165GLBI-2606-S7352Medutest2026-Q399.478.60Supplier-supplied1MARGINAL
AX-2026-043166GLBI-2606-S7352Janoshik2026-Q399.018.84105.4Laboratory-retained1MARGINAL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
Medutest199.4799.4725min+0.0899.39
Janoshik199.0199.0130min+0.0099.01

This lot contributes 1 paired comparison to the inter-lab analysis.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.2899.47divergence +0.04 pp vs batch median
Total impurities (% area)0.720.53
Largest single impurity (% area)not stated0.33
Water (%)7.58.60
Counter-ion (%)not statedN/A
Peptide content (%w/w)not statednot determined
Endotoxin (EU/mg)not statednot determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
glutathione disulfide (GSSG, +305 Da)2 / 20.240.16–0.33
cysteinyl-glycine (−129 Da)2 / 20.100.07–0.12
γ-Glu-Cys (−57 Da)2 / 20.050.05–0.05
S-sulfonate adduct (+80 Da)2 / 20.370.03–0.71
Section 6

Shared-bulk links

Rule AX-R09. Where impurity fingerprints and latent composition match across companies, the index treats the material as one bulk and counts it once in aggregates.

LotSold byRoleReportsMedian purity
HOMO-2408-R3237Homopeptidelinked child499.01
SWB-2506-B7923SWBlinked child799.00
GLBI-2606-S7352GL Biochemthis lot299.24
Section 7

What this rollup does not establish