AssayIndex

CPC-2405-F2639

Ipamorelin · 5 mg declared · Chinese Peptide Company Co., Ltd. · manufactured 26 May 2024

SINGLE TEST
Lot code
CPC-2405-F2639
Supplier
CPC — Chinese Peptide Company Co., Ltd.
Compound
Ipamorelin
Compound class
Growth-hormone axis peptides
Declared label claim
5mg
Manufacture date
26 May 2024
Index quarter
2024-Q3
Independent assays
1
Laboratories involved
PeptideMeter
Provenance mix
Buyer-sourced ×1
Section 1

Reproducibility across independent tests

Every report below is an observation of the same physical material. What they disagree about is measurement; what they agree about is the lot. The size of the disagreement is compared against what the contributing laboratories' own repeatability figures predict.

Independent assays 1
Median purity 98.74% n=1
Spread (max − min) n<2 n=1
Standard deviation n<3 n=1
97.197.698.198.699.199.6100.1All IpamorelinAll Ipamorelin: Q1 98.97, median 99.48, Q3 99.93, n=223outlier 97.34outlier 97.51n=223 Purity (% area)
Figure 1. This lot's independent purity results against the whole Ipamorelin record set in the index. The vertical line is the index acceptance specification for the growth-hormone axis peptides class, 99.0 % area. A narrow box on the top row against a wide box on the bottom row is the ideal reading: it means the disagreement between lots is much larger than the disagreement within this one.
Section 2

Member reports 1

Every report the index holds on this lot. Each is a page carrying its own chromatogram, mass spectrum, mass balance, provenance and caveats.

ReportLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2024-005364CPC-2405-F2639PeptideMeter2024-Q398.742.62Buyer-sourced2FAIL
Section 3

By laboratory

Where more than one laboratory assayed this lot, the difference between them is a paired observation of their relative bias — the same material, the same time window, different instruments. Those pairs are what the index's bias estimates are built from.

LaboratoryReportsPurity results (% area)MedianGradientPublished bias (pp)Bias-adjusted
PeptideMeter198.7498.7428min-0.0598.79

A single laboratory assayed this lot, so it contributes no paired comparison and the bias-adjusted column is a subtraction rather than a measurement.

Section 4

The supplier's certificate for this lot

One number the supplier wrote, beside the median of the numbers other people measured on the same physical material. That comparison is only available because the index groups by lot.

FigureSupplier COAThis reportIndex note
Purity (% area)99.598.74divergence +0.76 pp vs batch median
Total impurities (% area)not stated1.26
Largest single impurity (% area)not stated0.51
Water (%)1.62.62
Counter-ion (%)6.66.79
Peptide content (%w/w)91.2not determined
Endotoxin (EU/mg)0.30not determined
Method stated on certificateYEScolumn, gradient and wavelength given
Section 5

Impurity fingerprint

The named impurities reported across this lot's assays, with how consistently each was seen. A fingerprint is what allows two lot numbers held by different companies to be identified as one bulk.

Named impurityReported inMedian % areaRange
des-Lys (−128 Da)1 / 10.51
C-terminal free acid (+1 Da)1 / 10.31
[D-Trp]-epimer1 / 10.19
Aib-deletion sequence (−85 Da)1 / 10.14
oxidised Trp (+16 Da)1 / 10.11
Section 7

What this rollup does not establish