Twenty suppliers, sixty-six compounds, and the multiplicity problem.

first seen 2025-Q10 records submitted3 annotations
Section 1

Contribution

Comments technically on records submitted by others. Annotations are signed and are not moderated for agreement.

Records submitted 0 n=0
Annotations 3 n=3
Median purity submitted suppressed n=0 n<3 — see individual records
Suppliers covered 0 n=0

This handle has submitted no records. Annotators comment on other people's submissions and are not required to submit.

Section 2

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it.

AX-2026-042165
5.37 EU/mg is elevated relative to the index median and the record shows no depyrogenation step. If this material will be reconstituted in aqueous buffer for any downstream use, that endotoxin load is a risk.
AX-2025-020863
Endotoxin determined but the LAL method is not stated. Kinetic chromogenic and gel-clot give different results and different sensitivity. The value cannot be interpreted without knowing which.
AX-2025-020641
8.03 EU/mg but the material was passed through a sterile sterile filter. Some filters leach endotoxins; the measurement does not distinguish material from filter contribution.