Bacterial endotoxin testing, gel-clot and chromogenic. Sceptical of unstated methods.

first seen 2024-Q47 records submitted20 annotations
Section 1

Contribution

Both submits records and annotates other people's.

Records submitted 7 n=7
Annotations 20 n=20
Median purity submitted 98.98% n=7
Suppliers covered 5 n=7
Section 2

Records submitted

A submitter chose to buy this material and to pay for this assay. That choice is the selection mechanism behind the whole index and it is not random.

ReportCompoundSupplierLotLabQuarterPurity %Water %Recovery %ProvenanceFlagsResult
AX-2026-042291GHRP-6HJHJ-2603-R2258Janoshik2026-Q399.602.94101.3Supplier-supplied2MARGINAL
AX-2026-041434BPC-157QYBQYB-2601-D4733PeptideMeter2026-Q299.614.2689.6Supplier-supplied2MARGINAL
AX-2026-042284SemaglutideHomopeptideHOMO-2604-M2254Janoshik2026-Q299.512.48Supplier-supplied2MARGINAL
AX-2025-021117TB-500WXTWXT-2507-J5534Janoshik2025-Q498.203.69Supplier-supplied3FAIL
AX-2024-004967SermorelinGGPepsGGPE-2409-C8719Medutest2024-Q498.276.5292.7Supplier-supplied0PASS
AX-2024-004738RetatrutideHomopeptideHOMO-2405-B9038Janoshik2024-Q397.765.8491.6Buyer-sourced2MARGINAL
AX-2024-004726GHK-CuHomopeptideHOMO-2408-C8560Nordanalyt2024-Q398.985.18Supplier-supplied0PASS
SupplierRecordsMedian purity
Homopeptide398.98
HJ1n<3
QYB1n<3
WXT1n<3
GGPeps1n<3
Section 3

Annotations

Signed technical comments on records. The index does not moderate annotations for agreement with its own arithmetic, and several of these disagree with it.

AX-2026-041651
5.19 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-041428
5.51 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-041705
7.28 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-042617
14.67 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-041708
5.66 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-042162
5.09 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-042844
5.54 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2026-042165
5.37 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2025-020057
6.17 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2025-020865
10.00 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2025-020640
6.06 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.
AX-2025-020708
8.85 EU/mg is above the index screening threshold of 5.0. Two things to keep separate: the index threshold is a screening figure, and a real limit is dose-dependent. The endotoxin dose-limit calculator does that arithmetic. What this record establishes is that the burden is measurable and high relative to the rest of the dataset.

Showing 12 of 20.